ABB Soft starter Price List

Model Description Leading Price
TechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 30 kW(400 V) 55 kW(500 V) 75 kWRated Operational Current - In-Line Connection (Ie):106 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE105Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection
In Stock
Subscribe
Rated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 11 kW(400 V) 22 kW(500 V) 30 kWRated Operational Current - In-Line Connection (Ie):45 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE45Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 15 kW(400 V) 30 kW(500 V) 37 kWRated Operational Current - In-Line Connection (Ie):60 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE60Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 18.5 kW(400 V) 37 kW(500 V) 45 kWRated Operational Current - In-Line Connection (Ie):72 AService Factor Percentage:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial Voltage During Start:30 ... 70 %Step Down Voltage Special Ramp:No %Current Limit Function:1.5 ... 7xIeSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:4…20 mASignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:Modbus-RTUDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmRigid 1/2 x 2.5 ... 70 mm²Width and Thickness 17.5x5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Control Circuit 0.5 N·mMain Circuit 9 N·mSupply Circuit 0.5 N·mProduct Main Type:PSE72Function:Soft start with torque controlSoft start with voltage rampSoft stop with torque controlSoft stop with voltage rampKick startSequence startCurrent limitStart reverse (external contactors)Automatic restartEvent logProtection Function:Electronic overload protection, EOL; Locked rotor protection; Current underload protection
In Stock
Subscribe
OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:Softstarter PSR3 ... PSR16 for 100-240VInstructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:114 mmProduct Net Height:140 mmProduct Net Depth / Length:45 mmProduct Net Weight:0.4 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 3 kW(400 V) 5.5 kW(500 V) 5.5 kWRated Operational Current - In-Line Connection (Ie):12 AService Factor Percentage:100 %Overload Protection:Recommended MS132 10.00 ... 16.00Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:NoFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 1 N·mMain Circuit 1 N·mSupply Circuit 1 N·mProduct Main Type:PSR12Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 3 Hp(440 ... 480 V AC) Three Phase 7.5 Hp(550 ... 600 V AC) Three Phase 10 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 8.9 in·lbMain Circuit 8.9Supply Circuit 8.9 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CE:1SFA1-86Container InformationPackage Level 1 Width:121 mmPackage Level 1 Depth / Length:50 mmPackage Level 1 Height:156 mmPackage Level 1 Gross Weight:0.5 kgPackage Level 1 EAN:7320500338247Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter
In Stock
Subscribe
OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:Softstarter PSR3 ... PSR16 for 100-240VInstructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:114 mmProduct Net Height:140 mmProduct Net Depth / Length:45 mmProduct Net Weight:0.4 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 4 kW(400 V) 7.5 kW(500 V) 7.5 kWRated Operational Current - In-Line Connection (Ie):16 AService Factor Percentage:100 %Overload Protection:Recommended MS132 10.00 ... 16.00Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:NoFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1/2 x 0.75 ... 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1/2 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 1 N·mMain Circuit 1 N·mSupply Circuit 1 N·mProduct Main Type:PSR16Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 3 Hp(220 ... 240 V AC) Three Phase 5 Hp(440 ... 480 V AC) Three Phase 10 Hp(550 ... 600 V AC) Three Phase 10 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 8.9 in·lbMain Circuit 8.9Supply Circuit 8.9 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR3,6,9,12,16-600-70, PSRC3,6,9,12,16-600-70, PSR3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-11, PSRC3,6,9,12,16-600-70-1, Made in ChinaDeclaration of Conformity - CE:1SFA1-86Container InformationPackage Level 1 Width:121 mmPackage Level 1 Depth / Length:50 mmPackage Level 1 Height:156 mmPackage Level 1 Gross Weight:0.5 kgPackage Level 1 EAN:7320500338261Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter
In Stock
Subscribe
OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:1SFC132032M0001Instructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:153 mmProduct Net Height:187 mmProduct Net Depth / Length:54 mmProduct Net Weight:1 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 11 kW(400 V) 22 kW(500 V) 30 kWRated Operational Current - In-Line Connection (Ie):45 AService Factor Percentage:100 %Overload Protection:Recommended MS450 36 ... 45Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10Terminal Type:Screw TerminalsConnecting Capacity Main Circuit:Rigid 1x 6 ... 35 mm²Rigid 2 x 6 ... 16 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1 x 0.75 ... 2.5 mm²Rigid 2 x 0.75 ... 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 0.6 N·mMain Circuit 4 N·mSupply Circuit 0.6 N·mProduct Main Type:PSR45Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 15 Hp(220 ... 240 V AC) Three Phase 15 Hp(440 ... 480 V AC) Three Phase 30 Hp(550 ... 600 V AC) Three Phase 40 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 5.3 in·lbMain Circuit 35.4Supply Circuit 5.3 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR37-600-70, PSR45-600-70, PSRC37-600-70, PSRC45-600-70, PSR37-600-11, PSR45-600-11, PSRC37-600-11, PSRC45-600-11, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR37-600-70, PSR45-600-70, PSRC37-600-70, PSRC45-600-70, PSR37-600-11, PSR45-600-11, PSRC37-600-11, PSRC45-600-11, Made in ChinaDeclaration of Conformity - CE:1SFA1-91Container InformationPackage Level 1 Width:163 mmPackage Level 1 Depth / Length:56 mmPackage Level 1 Height:217 mmPackage Level 1 Gross Weight:1.1 kgPackage Level 1 EAN:7320500338346Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter
In Stock
Subscribe
OrderingMinimum Order Quantity:1 pieceCustoms Tariff Number:85371091Popular DownloadsData Sheet, Technical Information:Softstarter main catalogInstructions and Manuals:Softstarter PSR60 ... PSR105 for 100 - 240VInstructions and Manuals (Part 3):Softstarter HandbookCAD Dimensional Drawing:Information - 2D and 3D files for CAD systemsWiring Diagram:N/ADimensionsProduct Net Width:180 mmProduct Net Height:220 mmProduct Net Depth / Length:70 mmProduct Net Weight:2.1 kgTechnicalRated Operational Voltage:208 ... 600 V ACRated Control Supply Voltage (Us):100 ... 240 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 22 kW(400 V) 37 kW(500 V) 45 kWRated Operational Current - In-Line Connection (Ie):72 AService Factor Percentage:100 %Overload Protection:Recommended MS495 57 ... 75Integrated Electronic Overload:NoStarting Capacity at Maximum Rated Current Ie:4xIe for 6sRamp Time:0 ... 20 second [unit of time]1 ... 10 second [unit of time]Initial Voltage During Start:40 ... 70 %Step Down Voltage Special Ramp:100 ... 60 %Current Limit Function:NoSwitch for Inside Delta Connection:NoRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:NoOverload Signal Relay:NoSignal Indication Completed Start Ramp (LED):GreenSignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Ramping Up/Down (LED):GreenNumber of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10Communication:FiledBusPlug(Optional)Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10Terminal Type:Main Circuit: BarsConnecting Capacity Main Circuit:Rigid 1x 10 ... 95 mm²Rigid 2 x 6 ... 35 mm²Connecting Capacity Control Circuit:1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1 x 0.75 ... 2.5 mm²Rigid 2 x 0.75 ... 1.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 0.75 ... 2.5 mm²Tightening Torque:Control Circuit 0.6 N·mMain Circuit 8 N·mSupply Circuit 0.6 N·mProduct Main Type:PSR72Function:Soft start with voltage rampSoft stop with voltage rampTechnical UL/CSAHorsepower Rating UL/CSA:(200 ... 208 V AC) Three Phase 20 Hp(220 ... 240 V AC) Three Phase 25 Hp(440 ... 480 V AC) Three Phase 50 Hp(550 ... 600 V AC) Three Phase 60 HpMaximum Operating Voltage UL/CSA:Main Circuit 600 VTightening Torque UL/CSA:Control Circuit 5.3 in·lbMain Circuit 70.8Supply Circuit 5.3 in·lbEnvironmentalAmbient Air Temperature:Operation -25 ... +60 °CStorage -40 ... +70 °CMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACh Declaration for all SoftstartersRoHS Information:RoHS II Declaration for all SoftstartersRoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for SoftstartersWEEE B2C / B2B:Business To BusinessWEEE Category:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCQC Certificate:CQC Certificate, Softstarters, PSR60-600-70,PSR72-600-70,PSR85-600-70,PSR105-600-70,PSRC60-600-70,PSRC72-600-70,PSRC85-600-70,PSRC105-600-70,PSR60-600-11,PSR72-600-11,PSR85-600-11,PSR105-600-11,PSRC60-600-11,PSRC72-600-11,PSRC85-600-11,PSRC105-600-11, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Softstarters, PSR60-600-70,PSR72-600-70,PSR85-600-70,PSR105-600-70,PSRC60-600-70,PSRC72-600-70,PSRC85-600-70,PSRC105-600-70,PSR60-600-11,PSR72-600-11,PSR85-600-11,PSR105-600-11,PSRC60-600-11,PSRC72-600-11,PSRC85-600-11,PSRC105-600-11, Made in ChinaDeclaration of Conformity - CE:1SFA1-95Container InformationPackage Level 1 Width:195 mmPackage Level 1 Depth / Length:86 mmPackage Level 1 Height:230 mmPackage Level 1 Gross Weight:2.3 kgPackage Level 1 EAN:7320500362617Package Level 1 Units:box 1 pieceExternal Classifications and StandardsObject Classification Code:QETIM 7:EC000640 - Soft starterETIM 8:EC000640 - Soft starterETIM 9:EC000640 - Soft startereClass:V11.0 : 27370907UNSPSC:39121521IDEA Granular Category Code (IGCC):4740 >> Soft starter
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 30 kW(400 V) 55 kW(500 V) 75 kW(690 V) 90 kWRated Operational Current - In-Line Connection (Ie):105 ARated Operational Power - Inside Delta Connection:at 230 V 55 kWat 400 V 90 kWat 500 V 110 kWat 690 V 160 kWRated Operational Current - Inside Delta Connection:181 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX105Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 37 kW(400 V) 75 kW(500 V) 90 kW(690 V) 132 kWRated Operational Current - In-Line Connection (Ie):142 ARated Operational Power - Inside Delta Connection:at 230 V 75 kWat 400 V 132 kWat 500 V 160 kWat 690 V 220 kWRated Operational Current - Inside Delta Connection:245 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 14 N·mProduct Main Type:PSTX142Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 59 kW(400 V) 110 kW(500 V) 132 kW(690 V) 184 kWRated Operational Current - In-Line Connection (Ie):210 ARated Operational Power - Inside Delta Connection:at 230 V 102 kWat 400 V 184 kWat 500 V 250 kWat 690 V 315 kWRated Operational Current - Inside Delta Connection:360 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Main Circuit:Hole Diameter 10.2 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 25 N·mProduct Main Type:PSTX210Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
Technical parametersRated Operating Voltage:208 ... 690 V ACRated control supply voltage (U.)s):100 ... 250 V ACRated control circuit voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operating Power - Coaxial Connection (PE):(230 V) 75 kW(400 V) 132 kW(500 V) 160 kW(690 V) 220 kWRated Operating Current - Coaxial Connection (IE):250 ARated Operating Power - Inner Delta Connection:at 230 V 132 kWat 400 V 220 kWat 500 V 295 kWat 690 V 400 kWRated Operating Current - Inner Delta Connection:430 APercentage of Safety Factor:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting capacity at maximum rated current Ie:4xIe for 10sSlope Time:1 ... 120 second [unit of time]Initial voltage at start-up:10 ... 99 %Special Buck Ramps:100 ... 10 %Current Limiting Function:1.5 ... 7.5 xleInner triangle connection switch:beRunning Signal Relay:beBypass Signal Relay:YesFault Signal Relays:YesOverload Signal Relay:beAnalog Output:0… 10 V, 0... 20 mA, 4... 20 mAReady to start/standby signal indication ON (LED):GreenOperational signal indication R (LED):GreenProtection Signal Indication (LED):YellowFault Signal Indication (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPIngress Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsMain circuit connection capacity:Hole Diameter 8.5 mmControl circuit connection capacity:Rigid 1 x 2.5 mm²Power supply circuit connection capacity:Rigid 1 x 2.5 mm²Tightening torque:Main Circuit 25 N·mProduct range:PSTX250Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Functions:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 7.5 kW(400 V) 15 kW(500 V) 18.5 kW(690 V) 25 kWRated Operational Current - In-Line Connection (Ie):30 ARated Operational Power - Inside Delta Connection:at 230 V 12.5 kWat 400 V 25 kWat 500 V 30 kWat 690 V 45 kWRated Operational Current - Inside Delta Connection:52 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX30Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 9 kW(400 V) 18.5 kW(500 V) 22 kW(690 V) 30 kWRated Operational Current - In-Line Connection (Ie):37 ARated Operational Power - Inside Delta Connection:at 230 V 15 kWat 400 V 30 kWat 500 V 37 kWat 690 V 55 kWRated Operational Current - Inside Delta Connection:64 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX37Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
Technical parametersRated Operating Voltage:208 ... 690 V ACRated control supply voltage (U.)s):100 ... 250 V ACRated control circuit voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operating Power - Coaxial Connection (PE):(230 V) 160 kW(400 V) 315 kW(500 V) 400 kW(690 V) 560 kWRated Operating Current - Coaxial Connection (IE):570 ARated Operating Power - Inner Delta Connection:at 230 V 295 kWat 400 V 540 kWat 500 V 700 kWat 690 V 960 kWRated Operating Current - Inner Delta Connection:987 APercentage of Safety Factor:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting capacity at maximum rated current Ie:4xIe for 10sSlope Time:1 ... 120 second [unit of time]Initial voltage at start-up:10 ... 99 %Special Buck Ramps:100 ... 10 %Inner triangle connection switch:beRunning Signal Relay:beBypass Signal Relay:YesFault Signal Relays:YesOverload Signal Relay:beReady to start/standby signal indication ON (LED):GreenOperational signal indication R (LED):GreenProtection Signal Indication (LED):YellowFault Signal Indication (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPIngress Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsControl circuit connection capacity:Rigid 1 x 2.5 mm²Power supply circuit connection capacity:Rigid 1 x 2.5 mm²Tightening torque:Main Circuit 35 N·mProduct range:PSTX570Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Functions:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 15 kW(400 V) 30 kW(500 V) 37 kW(690 V) 55 kWRated Operational Current - In-Line Connection (Ie):60 ARated Operational Power - Inside Delta Connection:at 230 V 30 kWat 400 V 55 kWat 500 V 75 kWat 690 V 90 kWRated Operational Current - Inside Delta Connection:105 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0 ... 10 V, 0 ... 20 mA, 4 ... 20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX60Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 18.5 kW(400 V) 37 kW(500 V) 45 kW(690 V) 59 kWRated Operational Current - In-Line Connection (Ie):72 ARated Operational Power - Inside Delta Connection:at 230 V 37 kWat 400 V 59 kWat 500 V 80 kWat 690 V 110 kWRated Operational Current - Inside Delta Connection:124 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX72Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 200 kW(400 V) 400 kW(500 V) 500 kW(690 V) 710 kWRated Operational Current - In-Line Connection (Ie):720 ARated Operational Power - Inside Delta Connection:at 230 V 355 kWat 400 V 710 kWat 500 V 880 kWat 690 V 1200 kWRated Operational Current - Inside Delta Connection:1247 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 45 N·mProduct Main Type:PSTX720Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 250 kW(400 V) 450 kW(500 V) 600 kW(690 V) 800 kWRated Operational Current - In-Line Connection (Ie):840 ARated Operational Power - Inside Delta Connection:at 230 V 450 kWat 400 V 800 kWat 500 V 1000 kWat 690 V 1400 kWRated Operational Current - Inside Delta Connection:1455 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 45 N·mProduct Main Type:PSTX840Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
TechnicalRated Operational Voltage:208 ... 690 V ACRated Control Supply Voltage (Us):100 ... 250 V ACRated Control Circuit Voltage (Uc):24 V DCRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operational Power - In-Line Connection (Pe):(230 V) 22 kW(400 V) 45 kW(500 V) 55 kW(690 V) 75 kWRated Operational Current - In-Line Connection (Ie):85 ARated Operational Power - Inside Delta Connection:at 230 V 40 kWat 400 V 75 kWat 500 V 90 kWat 690 V 132 kWRated Operational Current - Inside Delta Connection:147 AService Factor Percentage:100 %Overload Protection:Built-in electronic overload protectionIntegrated Electronic Overload:YesStarting Capacity at Maximum Rated Current Ie:4xIe for 10sRamp Time:1 ... 120 second [unit of time]Initial Voltage During Start:10 ... 99 %Step Down Voltage Special Ramp:100 ... 10 %Current Limit Function:1.5 ... 7.5 xleSwitch for Inside Delta Connection:YesRun Signal Relay:YesBy-pass Signal Relay:YesFault Signal Relay:YesOverload Signal Relay:YesAnalog Outputs:0…10 V, 0…20 mA, 4…20 mASignal Indication Ready to Start/Standby ON (LED):GreenSignal Indication Running R (LED):GreenSignal Indication Protection (LED):YellowSignal Indication Fault (LED):RedCommunication:Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTPDegree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Cable ClampConnecting Capacity Main Circuit:Hole Diameter 8.5 mmConnecting Capacity Control Circuit:Rigid 1 x 2.5 mm²Connecting Capacity Supply Circuit:Rigid 1 x 2.5 mm²Tightening Torque:Main Circuit 8 N·mProduct Main Type:PSTX85Function:Auto phase sequence detectionAutomatic restartCurrent limitCurrent limit rampDual current limitDynamic brakeElectricity meteringElectronic overload Time-to-coolEmergency modeEvent logShow moreProtection Function:Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protectionWarning Details:Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
In Stock
Subscribe
Unsubscribe

Discount Code

Subscribe
Please check the item(s) you are interested in. (required)

Enter email to obtain information:

Verification code:

verify-code
USE : 0.2145938873291