Keyence Fiber Optic Sensors Price List
Model | Description | Leading | Price |
---|---|---|---|
ModelFU-V84L*1TypeVacuum-side fiber unit (thrubeam model heat resistant to 350°C 662°F, M4 elbow type)Detecting methodThrubeamFibre unit length1 m39.37"Minimum bend radiusR25 mm0.984" or moreMinimum detectable objectOpaque material with a diameter of 0.005 mm0.0002" *2Environmental resistanceAmbient temperature-40 to +350 °C -40 to 662 °FWeightApprox. 60 g*1 For details on the detecting distance, see the fiber amplifier catalog.*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.
|
In Stock
|
Subscribe
|
|
ModelF-1*1TypeSide viewCompatible fiberFU-77V/77 ,FU-77G ,FU-7F/86A ,FU-86Z ,FU-78/84C/88KEnvironmental resistanceAmbient temperature-40 to +70 °C -40 to 158 °F*2WeightApprox. 2 g*1 For details on the detecting distance, see the fiber amplifier catalog.*2 To use the F-1 at a temperature of 70 °C 158 °F or more, use the F-1 with heat resistant specifications. Use the F-1 with heat resistant specifications at a constant temperature.
|
In Stock
|
Subscribe
|
|
ModelF-2*1TypeLong distance (aperture angle : Approx 15°)Compatible fiberFU-77TZ/77/77/84C/88K ,FU-7F/86A ,FU-86Z ,FU-78/84C/88K ,FU-77G/77TGEnvironmental resistanceAmbient temperature-40 to +300 °C -40 to 572 °FWeightApprox. 2 g*1 For details on the detecting distance, see the fiber amplifier catalog.
|
In Stock
|
Subscribe
|
|
ModelF-2HATypeSmall beam spot lensCombinable fiber unitFU-24X,FU-21X,FU-35FZ,FU-35FG,FU-35FA,FU-35TZ,FU-35TGSpot diameterApprox 0.1 (FU-24X), Approx 0.2 (FU-21X), Approx 0.4 (FU-35FZ, FU-35FG, FU-35FA, FU-35TZ, FU-35TG)Detection focal distance7 ±2 mm0.276" ±0.079"*1Environmental resistanceAmbient temperature-30 to +70 °C -22 to 158 °FWeightApprox. 1 g*1 When using the FS-N10 Series and FS-V30 Series.
|
In Stock
|
Subscribe
|
|
ModelF-3HA*1TypeParallel light lensCombinable fiber unitFU-35FZ,FU-35FG,FU-35FA,FU-35TZ,FU-35TGSpot diameterApprox 4 mm0.157" (at 0 to 20 mm0" to 0.787")Environmental resistanceAmbient temperature-30 to +70 °C -22 to 158 °FWeightApprox. 2 g*1 For details on the detecting distance, see the fiber amplifier catalog.
|
In Stock
|
Subscribe
|
|
ModelF-4*1TypeUltra long distance, focused beam (aperture angle : Approx 8°)Compatible fiberFU-77TZ/77V/77 ,FU-7F ,FU-78 ,FU-77G/77TGEnvironmental resistanceAmbient temperature-40 to +70 °C -40 to 158 °FWeightApprox. 1 g*1 For details on the detecting distance, see the fiber amplifier catalog.
|
In Stock
|
Subscribe
|
|
ModelF-5*1TypeSide view with mounting holesCompatible fiberFU-77V/77 ,FU-7F/86A ,FU-86Z ,FU-78 ,FU-77GEnvironmental resistanceAmbient temperature-40 to +105 °C -40 to 221 °FWeightApprox. 10 g*1 For details on the detecting distance, see the fiber amplifier catalog.
|
In Stock
|
Subscribe
|
|
ModelF-5HATypeSide view, variable spot lensCombinable fiber unitFU-35FZ,FU-35FG,FU-35FASpot diameterø0.5 to 3 mmø0.02" to 0.118"Detection focal distance8 to 30 mm0.315" to 1.181"*1WeightApprox. 2 g*1 When using the FS-N10 Series and FS-V30 Series.
|
In Stock
|
Subscribe
|
|
ModelFS-MC8NOutputNPNResponse timeDepends on the response time settings of the connected expansion unitsExternal inputInput time of the connected expansion units +11 msNumber of inputs and outputsSeparate control outputs: 8, common output: 1, common input: 1Unit expansionUp to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.) Allowable passing current: 1200 mA or lessIndicatorsSTATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange)Separate control output,common outputNPN open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.4 V or lessProtection circuitProtection against reverse power connection, reverse output connection, output overcurrent, and output surgePower supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*1Power consumption690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current] )*2Environmental resistanceAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 110 g*1 Match the rated power supply voltage of the expansion units to be connected to the system.*2 The power consumption including the load when the maximum number of units are connected is 38 W max.
|
In Stock
|
Subscribe
|
|
ModelFS-N44PTypeCableOutputPNPMain unit/expansion unitExpansion unitResponse time23 µs (S-HSPD*1*2) /50 µs (HSPD*3) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)Number of control outputs2Number of external inputs1Light source LEDTransmitter side: Red, four-element LED (wavelength: 660 nm)Control outputOpen-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)Residual voltage: 1.6 V or less (output current: 10 mA or less) /2.2 V or less (output current: 10 to 100 mA)External inputInput time: 2 ms (ON) /20 ms (OFF) or longer*4Unit expansionUp to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.Protection circuitProtection against reverse power connection, output overcurrent, output surge, and reverse output connectionMutual interference preventionS-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)Power supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5Power consumptionDuring normal operation: 990 mW or less (39 mA or less at 24 V/72 mA or less at 12 V)ECO ON: 920 mW or less (36 mA or less at 24 V/66 mA or less at 12 V)ECO FULL: 830 mW or less (33 mA or less at 24 V / 59 mA or less at 12 V)*6Environmental resistanceAmbient lightIncandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or lessAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)*7Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 73 g*1 Restrictions when S-HSPD is selected: Output 2 of dual output types is fixed to OFF.*2 Restrictions when S-HSPD is selectedArea detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.Output timer, Limit Detection, and Display Gain cannot be used.FULL cannot be selected for the ECO function.*3 Restrictions when HSPD is selectedDisplay Gain cannot be used.*4 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.*5 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.*6 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.*7 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.Exercise special care when installing the product in an airtight space.
|
In Stock
|
Subscribe
|
|
ModelOP-88245TypeAmplifier securing bracket (for main unit)OverviewIt can be mounted without the DIN rail.
|
In Stock
|
Subscribe
|
|
ModelFS-N10Type0-lineMain unit/expansion unitExpansionunit(No outputcable)Control outputN/A*1Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 20 g*1 Counted as 1 output when connecting with the network unit NU Series.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N11CNTypeStandard 1 outputM8 connector*1OutputNPNMain unit/expansion unitMain unitControl output1NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)-External input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 22 g*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N11CPTypeStandard 1 outputM8 connector*1OutputPNPMain unit/expansion unitMain unitControl output1PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessExternal input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*2Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*2Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 22 g*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N11MNTypeMonitor outputCableOutputNPNMain unit/expansion unitMain unitControl output1NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)1External input-Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 75 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N11NTypeStandard 1 outputCableOutputNPNMain unit/expansion unitMain unitControl output1NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)-External inputLight source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 75 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N12CNTypeStandard 1 outputM8 connector*1OutputNPNMain unit/expansion unitExpansion unitControl output1NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)-External input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 22 g*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N12CPTypeStandard 1 outputM8 connector*1OutputPNPMain unit/expansion unitExpansion unitControl output1PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessExternal input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*2Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*2Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 22 g*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N12NTypeStandard 1 outputCableOutputNPNMain unit/expansion unitExpansion unitControl output1NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)-External inputLight source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 45 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N12PTypeStandard 1 outputCableOutputPNPMain unit/expansion unitExpansion unitControl output1PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessExternal input-Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*1Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*1Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 45 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N13CPTypeHigh functionality 2 outputM8 connector*1OutputPNPMain unit/expansion unitMain unitControl output2PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessExternal input-Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)*2Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)*2Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 22 g*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N13NTypeHigh functionality 2 outputCableOutputNPNMain unit/expansion unitMain unitControl output2NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)-External input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 80 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N14CPTypeHigh functionality 2 outputM8 connector*1OutputPNPMain unit/expansion unitExpansion unitControl output2PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessExternal input-Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)*2Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)*2Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 22 g*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N14NTypeHigh functionality 2 outputCableOutputNPNMain unit/expansion unitExpansion unitControl output2NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessMonitor output (1-5 V)-External input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 70 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N14PTypeHigh functionality 2 outputCableOutputPNPMain unit/expansion unitExpansion unitControl output2PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or lessExternal input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Light source LEDRed, 4-element LEDAPCON/OFF switchable (Factory setting: OFF)Response time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA(When set to double, the number of interference-prevention units will be doubled.)Unit expansionUp to 16 units can be connected total (two output type is treated as two units)RatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)*1Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)*1Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V)Environmental resistanceAmbient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to +131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsCase materialBoth main unit and expansion unit housing material: PolycarbonateWeightApprox. 70 g*1 Increases 100 mW (4.0 mA) for High Speed mode*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
|
In Stock
|
Subscribe
|
|
ModelFS-N15CNTypeIP66 Fiberoptic Amplifier, 1 output typeOutputNPNI/O formatM8 connector *1Main unit/expansion unitMain unitControl output1 outputNPN open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or lessExternal input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Output toggleLight-ON/Dark-ON switchableLight source LEDRed 4-element LED (wavelength 630 nm)Timer functionTimer OFF/OFF delay/ON delay/One-shotResponse time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 units (expansion not possible)Case sizeH30.3mm 1.19" x W9.8mm 0.39" x L71.8mm 2.38"Unit expansion0 units (expansion not possible)Protection circuitReverse polarity protection, Over-current protection, Surge absorberRatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceEnclosure ratingIP66*3*4Ambient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsMaterialAdapterGlass-reinforced PBTWeightApprox. 30 g*1 Use a cable of 30 m 98.43' or less.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 About the enclosure rating when a small-diameter fiber unit (the diameter of the cable is ø1.3 or ø1.0) is used. IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/93/43/63/63T etc.) is used. When any small-diameter fiber units except for the above are used, IP65 is applied.*4 In any of the following cases, the enclosure rating IP66/IP65 cannot be satisfied.When the Fiber Unit and KEYENCE's M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first.Then retighten it as much as 1/16-1/8 of a rotation with pliers.)When the Fiber Unit and KEYENCE's M8 connector cable are not connectedWhen the dust cover of the Sensor Amplifier is openWhen there is debris in the dust coverWhen the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit.
|
In Stock
|
Subscribe
|
|
ModelSR-X300 *1TypeSR-X300: Standard type (2.3 megapixels)SR-X300 + SR-XHR: High-resolution typeReceiverSensorCMOS image sensorNumber of pixels1920 × 1200FocusAuto*2EmitterIllumination light sourceHigh-intensity red/white LED*3Pointer light sourceHigh-intensity green LED*3Reading specificationsSupported symbols2D codesQR, MicroQR, DataMatrix(ECC200), DMRE, GS1 DataMatrix, PDF417, MicroPDF417,GS1 Composite (CC-A/CC-B/CC-C), DotCode, Maxi Code, Aztec CodeBarcodesCODE39, ITF, 2of5 (Industrial 2of5), COOP 2of5, NW-7 (Codabar), CODE128, GS1-128, GS1 DataBar, CODE93,JAN/EAN/UPC, Trioptic CODE39, CODE39 Full ASCII, Pharmacode, Postal (Japan Postal, IMB)Minimum resolution2D codesSR-X300: 0.024 mm 0.0009"SR-X300 + SR-XHR: 0.010 mm 0.0004"Barcodes0.082 mm 0.0032"Reading distanceSR-X300: 70 to 1000 mm 2.76" to 39.37"SR-X300 + SR-XHR: 32 to 47 mm 1.26" to 1.85"Reading field of viewSR-X300: 104 × 65 mm 4.09" × 2.56"(at a distance of 300 mm 11.81")SR-X300 + SR-XHR: 12.3 × 7.7 mm 0.48" × 0.30"(at a distance of 47 mm 1.85")I/O specificationsControl inputNumber of inputs2Input typeBidirectional voltage inputMaximum rating30 VDCMinimum ON voltage15 VDCMaximum OFF current0.2 mAControl outputNumber of outputs3Output typePhoto MOS relay outputMaximum rating30 VDCMaximum load current50 mA or less for 1 output, or 100 mA or less in total for 3 outputsLeakage current when OFF0.1 mA or lessResidual voltage when ON1 V or lessEthernetCommunication standardIEEE 802.3-compliant 100BASE-TXSupported protocolsTCP/IP, SNTP, FTP, SFTP, HTTP, HTTPS, BOOTP, EtherNet/IP®, PROFINET, KV STUDIO, MC protocol, OMRON PLC linkSerial communicationCommunication standardRS-232C-compliantCommunication speed600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bpsSupported protocolsNo-protocol, KV STUDIO, MC protocol, SYSWAYUSBCommunication standardUSB 2.0 High Speed compliantRatingsPower voltage24 VDC +25%/-20%Current consumptionApprox. 750 mAEnvironmental resistanceEnclosure ratingIP65/IP67 (IEC60529)*4Ambient temperature0 to +45°C 32 to 113°FStorage temperature-10 to +50°C 14 to 122°FRelative humidity35 to 85% RH (No condensation)Storage relative humidityWeightSR-X300: Approx. 200 g 7.06 ozSR-X300 + SR-XHR: Approx. 225 g 7.94 oz*1 System ROM rewrites: 100000*2 The focal position can be adjusted automatically during installation or tuning.*3 LEDs and lamps are classified as shown below according to IEC 62471 (JIS C 7550).• Exempt group: Objects that do not cause any photobiological damage.• Risk group 1 (low risk): Objects that do not cause damage that makes constraints on normal actions necessary.• Risk group 2 (moderate risk): Objects that do not cause damage accompanied by unpleasant feelings and thermal discomfort.• Risk group 3 (high risk): Objects that cause damage even due to temporary or short-term exposure.The risk groups for this product are listed below.Pointer light source (Green): Risk group 1Illumination light source (Red): Risk group 1Illumination light source (White), Advance only: Risk group 1*4 Attach a USB port cover to meet the protective structural specification.
|
In Stock
|
Subscribe
|
|
ModelFS-N40TypeZero Line TypeMain unit/expansion unitExpansion unitResponse time23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)Number of control outputsNone*3Light source LEDTransmitter side: Red, four-element LED (wavelength: 660 nm)External inputInput time: 2 ms (ON) /20 ms (OFF) or longer*4Unit expansionUp to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.Protection circuitProtection against reverse power connection, output overcurrent, output surge, and reverse output connectionMutual interference preventionS-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)Power supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5Power consumptionDuring normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*6Environmental resistanceAmbient lightIncandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or lessAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)*7Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 23 g*1 Restrictions when S-HSPD is selectedArea detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.Output timer, Limit Detection, and Display Gain cannot be used.FULL cannot be selected for the ECO function.*2 Restrictions when HSPD is selectedDisplay Gain cannot be used.*3 This counts as 1 output when connecting multiple units to the FS-MC8N/P, NU Series.*4 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.*5 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.*6 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.*7 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.Exercise special care when installing the product in an airtight space.
|
In Stock
|
Subscribe
|
|
ModelFS-N41C*1TypeM8 Connector*2Main unit/expansion unitMain unitResponse time23 µs (S-HSPD*3) /50 µs (HSPD*4) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)Number of control outputs2*5Number of external inputs1*5Light source LEDTransmitter side: Red, four-element LED (wavelength: 660 nm)Control outputOpen-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)Residual voltageNPN 1.4 V or less (output current: 10 mA or less) /2 V or less (output current: 10 to 100 mA)PNP 1.6 V or less (output current: 10 mA or less) /2.2 V or less (output current: 10 to 100 mA)External inputInput time: 2 ms (ON) /20 ms (OFF) or longer*6Protection circuitProtection against reverse power connection, output overcurrent, output surge, and reverse output connectionMutual interference preventionS-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)Power supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*7Power consumptionDuring normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8Environmental resistanceAmbient lightIncandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or lessAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)*9Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 25 g*1 IO-Link Specifi cation V.1.1/COM2 (38.4 kbps) is supported.*2 Ensure the cable length is 30 m 98.4" or less for the M8 connector type. Ensure the cable length is 20 meters 65.6' or less when connecting by way of IO-Link.*3 Restrictions when S-HSPD is selectedOutput 2 of dual output types is fixed to OFF.IO-Link communication cannot be used.Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.Output timer, Limit Detection, and Display Gain cannot be used.FULL cannot be selected for the ECO function.*4 Restrictions when HSPD is selectedDisplay Gain cannot be used.*5 Output 2 and the external input are selectable.*6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.*7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.*8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.*9 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.Exercise special care when installing the product in an airtight space.
|
In Stock
|
Subscribe
|
|
ModelFS-N41NTypeCableOutputNPNMain unit/expansion unitMain unitResponse time23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)Number of control outputs1Number of external inputs―Light source LEDTransmitter side: Red, four-element LED (wavelength: 660 nm)Control outputOpen-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)Residual voltage: 1.4 V or less (output current: 10 mA or less) /2 V or less (output current: 10 to 100 mA)External inputInput time: 2 ms (ON) /20 ms (OFF) or longer*3Unit expansionUp to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.Protection circuitProtection against reverse power connection, output overcurrent, output surge, and reverse output connectionMutual interference preventionS-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)Power supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4Power consumptionDuring normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*5Environmental resistanceAmbient lightIncandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or lessAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)*6Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 78 g*1 Restrictions when S-HSPD is selectedArea detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.Output timer, Limit Detection, and Display Gain cannot be used.FULL cannot be selected for the ECO function.*2 Restrictions when HSPD is selectedDisplay Gain cannot be used.*3 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.*4 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.*5 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.*6 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.Exercise special care when installing the product in an airtight space.
|
In Stock
|
Subscribe
|