Keyence Photoelectric Sensors Price List
Model | Description | Leading | Price |
---|---|---|---|
|
In Stock
|
Subscribe
|
|
ModelCZ-H32TypeAdjustable spotDetecting area50 to 95 mm 1.97" to 3.74" (Reco mmended: 70 mm 2.76")Smallest spot diameterSmall: 3 mm 0.12"dia.Medium: 4.5 mm 0.18"dia.Large: 5.5 mm 0.22"dia.at respective reference distance*1Light sourceRed LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm)Minimum bend radius of fi ber25 mm 0.98"Environmental resistanceEnclosure ratingIP40Ambient lightIncandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.Ambient temperature-10 to +55 °C 14 to 131 °F (No freezing)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axisMaterialHousing:Fiberglass reinforced plastic , Lens cover:PolyarylateWeightApprox. 40 g*1 Reference distance: 65 mm 2.56” for Small, 60 mm 2.36” for Medium, and 50 mm 1.97” for Large
|
In Stock
|
Subscribe
|
|
ModelCZ-H35STypeLuster cancelDetecting area28 to 52 mm 1.10" to 2.05" (Reco mmended: 40 mm 1.57")Smallest spot diameter4.5 mm 0.18"dia. at referencedistance of 40 mm 1.57"Light sourceRed LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm)Minimum bend radius of fi ber25 mm 0.98"Environmental resistanceEnclosure ratingIP40Ambient lightIncandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.Ambient temperature-10 to +55 °C 14 to 131 °F (No freezing)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axisMaterialHousing:Triacetate, Polyarylate (Metal section: TYPE 304 stainless steel) , Lens cover:Fiberglass reinforced plasticWeightApprox. 40 g
|
In Stock
|
Subscribe
|
|
ModelCZ-H37STypeLuster-cancel, small beam spotDetecting area11 to 20 mm 0.43" to 0.79" (Reco mmended: 15 mm 0.59")Smallest spot diameter1 mm 0.04"dia. at referencedistance of 16 mm 0.63"Light sourceRed LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm)Minimum bend radius of fi ber15 mm 0.59"Environmental resistanceEnclosure ratingIP40Ambient lightIncandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.Ambient temperature-10 to +55 °C 14 to 131 °F (No freezing)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axisMaterialHousing:Triacetate, Polyarylate (Metal section: TYPE 304 stainless steel) , Lens cover:Fiberglass reinforced plasticWeightApprox. 45 g
|
In Stock
|
Subscribe
|
|
ModelCZ-H52TypeFluorescence detection UVDetecting area25 to 55 mm 0.98" to 2.17" (Reco mmended: 35 mm 1.38")Smallest spot diameterApprox. 10 mm 0.39 dia. at reference distance of 25 mm 0.98""Light sourceUV (ultraviolet) LED (375 nm) *1Minimum bend radius of fi ber―Receivable wavelength (Receiver)425 to 550 nmEnvironmental resistanceEnclosure ratingIP40Ambient lightIncandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.Ambient temperature-10 to +55 °C 14 to 131 °F (No freezing)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axisMaterialHousing:Fiberglass reinforced plastic , Lens cover:GlassWeightApprox. 40 g*1 The CZ-H52 emits ultraviolet light from the transmitter. Do not directly look at the lightsource while in operation.
|
In Stock
|
Subscribe
|
|
ModelCZ-V21AP*1OutputPNP outputMain unit/expansion unitMain unitResponse time200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER)Control outputPNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2Protection circuitReverse-polarity protection, overcurrent protection, surge absorberExternal tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode)Input time: 20 ms min.Timer functionTimer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)Unit expansionUp to 3 units (4 units total including the main unit)Number of interference prevention units0 for HIGH SPEED; 2 for FINE/TURBO/SUPERRatingPower voltage24 VDC, Ripple (P-P) 10 % or lessPower consumptionNormal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)Environmental resistanceAmbient temperature-10 to +55 °C 14 to 131 °F (No freezing)*3Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axisMaterialHousing, cover: PolycarbonateAccessoriesMounting FittingsWeightApprox. 110 g*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series tothe main unit of the FS-V20 Series.To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.*2 20 mA max. when several units are connected.*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA. When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F When 3 units are connected: -10 to +45 °C 14 to 113 °F
|
In Stock
|
Subscribe
|
|
ModelCZ-V21POutputPNP outputMain unit/expansion unitMain unitResponse time8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED)Control outputPNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1Protection circuitReverse-polarity protection, overcurrent protection, surge absorberExternal calibration inputNo-voltage input, input time: 20 ms or moreExternal shift inputTimer functionTimer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)Unit expansionUp to 3 units (4 units total including the main unit)*2RatingPower voltage24 VDC, Ripple (P-P) 10 % or lessPower consumptionNormal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)Environmental resistanceAmbient temperature-10 to +55 °C 14 to 131 °F (No freezing)*3Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axisMaterialHousing, cover: PolycarbonateWeightApprox. 110 g*1 20 mA max. when several units are connected.*2 The FS-V20 Series expansion unit cannot be connected to the CZ-V20 Series main unit. When using a combination of expansion units, connect the CZ-V20 Series expansion unit to the FS-V20 Series main unit. Also, if using multiple expansion units, make sure to connect the CZ-V20 Series to right side of the FS-V20 Series.*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output current to a maximum of 20 mA. When 1 or 2 units are connected: -10 to +50 °C 14 to 122 °F When 3 units are connected: -10 to +45 °C 14 to 113 °F
|
In Stock
|
Subscribe
|
|
ModelLR-TB2000TypeCableDetectable distance60 to 2000 mm 2.36" to 78.74"*1Spot diameterApprox. ø4 mm ø0.16"Light sourceTypeRed laser (660 nm)Laser classClass 2 laser product(IEC60825-1,FDA (CDRH) Part1040.10*2)Mutual interference prevention function4 units (when using the interference prevention function)TimerOFF/OFF delay/ON delay/One-shotResponse time1 ms/10 ms/25 ms/100 ms/1000 msselectableI/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, residual voltage: 2 V or less,N.O./N.C. selectable*3*4Analog output-Protection circuitProtection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surgePower voltage20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption45 mA or less (without load)*5Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp/Sunlight: 10,0000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover and buttons: PES,Lens cover and display: PMMA (scratch-resistant coating specifications),Cable bushing: PBT,Cable: PVCAccompanying itemsInstruction manual,Laser warning and explanation labelsWeightApprox. 125 g (Including cable)*1 The range for displayable distance is from 50 to 2200.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*3 You can select the I/O from the following combinations.Control output × 2, control output + external inputControl output + analog output (LR-TB5000/TB5000C/TB5000CL only)External input + analog output (LR-TB5000/TB5000C/TB5000CL only)(For details on the setting method, see the instruction manual.)*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*5 145 mA or less (with load)
|
In Stock
|
Subscribe
|
|
ModelLR-TB2000CTypeCable with connector M12Detectable distance60 to 2000 mm 2.36" to 78.74"*1Spot diameterApprox. ø4 mm ø0.16"Light sourceTypeRed laser (660 nm)Laser classClass 2 laser product(IEC60825-1,FDA (CDRH) Part1040.10*2)Mutual interference prevention function4 units (when using the interference prevention function)TimerOFF/OFF delay/ON delay/One-shotResponse time1 ms/10 ms/25 ms/100 ms/1000 msselectableI/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, residual voltage: 2 V or less,N.O./N.C. selectable*3*4Analog output-Protection circuitProtection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surgePower voltage20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption45 mA or less (without load)*5Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp/Sunlight: 10,0000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover and buttons: PES,Lens cover and display: PMMA (scratch-resistant coating specifications),Cable bushing: PBT,Cable: PVC,M12 connector: TPE, PBT, Nickel-plated brassAccompanying itemsInstruction manual,Laser warning and explanation labelsWeightApprox. 85 g*1 The range for displayable distance is from 50 to 2200.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*3 You can select the I/O from the following combinations.Control output × 2, control output + external inputControl output + analog output (LR-TB5000/TB5000C/TB5000CL only)External input + analog output (LR-TB5000/TB5000C/TB5000CL only)(For details on the setting method, see the instruction manual.)*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*5 145 mA or less (with load)
|
In Stock
|
Subscribe
|
|
ModelLR-TB2000CLTypeCable with connector M12Detectable distance60 to 2000 mm 2.36" to 78.74"*1Spot diameterApprox. ø4 mm ø0.16"Light sourceTypeRed laser (660 nm)Laser classClass 1 laser product(IEC60825-1,FDA (CDRH) Part1040.10*2)Mutual interference prevention function4 units (when using the interference prevention function)TimerOFF/OFF delay/ON delay/One-shotResponse time2 ms/20 ms/50 ms/200 ms/2000 msselectableI/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, residual voltage: 2 V or less,N.O./N.C. selectable*3*4Analog output-Protection circuitProtection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surgePower voltage20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption45 mA or less (without load)*5Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp/Sunlight: 10,0000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover and buttons: PES,Lens cover and display: PMMA (scratch-resistant coating specifications),Cable bushing: PBT,Cable: PVC,M12 connector: TPE, PBT, Nickel-plated brassAccompanying itemsInstruction manualWeightApprox. 85 g*1 The range for displayable distance is from 50 to 2200.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*3 You can select the I/O from the following combinations.Control output × 2, control output + external inputControl output + analog output (LR-TB5000/TB5000C/TB5000CL only)External input + analog output (LR-TB5000/TB5000C/TB5000CL only)(For details on the setting method, see the instruction manual.)*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*5 145 mA or less (with load)
|
In Stock
|
Subscribe
|
|
ModelLR-TB5000TypeCableDetectable distance60 to 5000 mm 2.36" to 196.85"*1Spot diameterVariable(use a spot diameter of 40 mm 1.57" or less)Light sourceTypeRed laser (660 nm)Laser classClass 2 laser product(IEC60825-1,FDA (CDRH) Part1040.10*2)Mutual interference prevention function4 units (when using the interference prevention function)TimerOFF/OFF delay/ON delay/One-shotResponse time1 ms/10 ms/25 ms/100 ms/1000 msselectableI/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, residual voltage: 2 V or less,N.O./N.C. selectable*3*4Analog outputCurrent output/Voltage output selectableCurrent output: 4 to 20 mA with a max. load resistance of 500 ΩVoltage output: 0 to 10 V with an external load resistance of 5 kΩ or more*3*4Protection circuitProtection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surgePower voltage20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption50 mA or less (without load)*5Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp/Sunlight: 10,0000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover and buttons: PES,Lens cover and display: PMMA (scratch-resistant coating specifications),Cable bushing: PBT,Cable: PVCAccompanying itemsInstruction manual,Laser warning and explanation labelsWeightApprox. 200 g (Including cable)*1 The range for displayable distance is from 50 to 5200.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*3 You can select the I/O from the following combinations.Control output × 2, control output + external inputControl output + analog output (LR-TB5000/TB5000C/TB5000CL only)External input + analog output (LR-TB5000/TB5000C/TB5000CL only)(For details on the setting method, see the instruction manual.)*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*5 150 mA or less(with load)
|
In Stock
|
Subscribe
|
|
ModelLR-TB5000CTypeCable with connector M12Detectable distance60 to 5000 mm 2.36" to 196.85"*1Spot diameterVariable(use a spot diameter of 40 mm 1.57" or less)Light sourceTypeRed laser (660 nm)Laser classClass 2 laser product(IEC60825-1,FDA (CDRH) Part1040.10*2)Mutual interference prevention function4 units (when using the interference prevention function)TimerOFF/OFF delay/ON delay/One-shotResponse time1 ms/10 ms/25 ms/100 ms/1000 msselectableI/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, residual voltage: 2 V or less,N.O./N.C. selectable*3*4Analog outputCurrent output/Voltage output selectableCurrent output: 4 to 20 mA with a max. load resistance of 500 ΩVoltage output: 0 to 10 V with an external load resistance of 5 kΩ or more*3*4Protection circuitProtection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surgePower voltage20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption50 mA or less (without load)*5Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp/Sunlight: 10,0000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover and buttons: PES,Lens cover and display: PMMA (scratch-resistant coating specifications),Cable bushing: PBT,Cable: PVC,M12 connector: TPE, PBT, Nickel-plated brassAccompanying itemsInstruction manual,Laser warning and explanation labelsWeightApprox. 160 g*1 The range for displayable distance is from 50 to 5200.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*3 You can select the I/O from the following combinations.Control output × 2, control output + external inputControl output + analog output (LR-TB5000/TB5000C/TB5000CL only)External input + analog output (LR-TB5000/TB5000C/TB5000CL only)(For details on the setting method, see the instruction manual.)*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*5 150 mA or less(with load)
|
In Stock
|
Subscribe
|
|
ModelLR-TB5000CLTypeCable with connector M12Detectable distance60 to 5000 mm 2.36" to 196.85"*1Spot diameterVariable(use a spot diameter of 40 mm 1.57" or less)Light sourceTypeRed laser (660 nm)Laser classClass 1 laser product(IEC60825-1,FDA (CDRH) Part1040.10*2)Mutual interference prevention function4 units (when using the interference prevention function)TimerOFF/OFF delay/ON delay/One-shotResponse time2 ms/20 ms/50 ms/200 ms/2000 msselectableI/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, residual voltage: 2 V or less,N.O./N.C. selectable*3*4Analog outputCurrent output/Voltage output selectableCurrent output: 4 to 20 mA with a max. load resistance of 500 ΩVoltage output: 0 to 10 V with an external load resistance of 5 kΩ or more*3*4Protection circuitProtection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surgePower voltage20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption50 mA or less (without load)*5Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp/Sunlight: 10,0000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover and buttons: PES,Lens cover and display: PMMA (scratch-resistant coating specifications),Cable bushing: PBT,Cable: PVC,M12 connector: TPE, PBT, Nickel-plated brassAccompanying itemsInstruction manualWeightApprox. 160 g*1 The range for displayable distance is from 50 to 5200.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*3 You can select the I/O from the following combinations.Control output × 2, control output + external inputControl output + analog output (LR-TB5000/TB5000C/TB5000CL only)External input + analog output (LR-TB5000/TB5000C/TB5000CL only)(For details on the setting method, see the instruction manual.)*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*5 150 mA or less(with load)
|
In Stock
|
Subscribe
|
|
ModelLR-W500Type2 m 6.56' cable typeDetecting distance30 to 500 mm 1.18" to 19.69"Min. spot diameterAdjustable spotApprox. ø3.5 mm at 100 mm ø0.14" at 3.94"Approx. ø9 mm at 250 mm ø0.35" at 9.84"Approx. ø18 mm at 500 mm ø0.71" at 19.69"Light sourceWhite LEDMutual interference reduction functionUp to 2 units when alternate frequencies setTimerOFF/ON delay/OFF delay/One-shotResponse time200 µs/1 ms/10 ms/100 ms/500 ms selectable *1I/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, remaining voltage: 2 V or lessN.O./N.C. selectable*2External inputTuning /Transmission OFF selectableShort circuit current: 1 mA or less for NPN/2 mA or less for PNPFor the applied voltage, see the wiring diagrams in the instruction manual.For the input times, see the time charts in the instruction manual.*2Protection circuitProtection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connectionPower supplyPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption65 mA or less (without load) at 24 VDC;120 mA or less (without load) at 12 VDC *3Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or lessAmbient temperature-20 to +50 °C -4 to 122 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover: PPSU, Buttons: PESLens cover and display: PMMA (scratch-resistant coating),Cable bushing: PBT, Cable: PVC, Spot adjustment dial: Iron (triiron tetraoxide coated)WeightApprox. 170 g (including cable)*1 When alternate frequencies are set, the response time increases by approximately 20%.*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*3 195 mA or less (at 10 V, with load)
|
In Stock
|
Subscribe
|
|
ModelLR-W500CTypeM12 connector 4-pin typeDetecting distance30 to 500 mm 1.18" to 19.69"Min. spot diameterAdjustable spotApprox. ø3.5 mm at 100 mm ø0.14" at 3.94"Approx. ø9 mm at 250 mm ø0.35" at 9.84"Approx. ø18 mm at 500 mm ø0.71" at 19.69"Light sourceWhite LEDMutual interference reduction functionUp to 2 units when alternate frequencies setTimerOFF/ON delay/OFF delay/One-shotResponse time200 µs/1 ms/10 ms/100 ms/500 ms selectable *1I/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, remaining voltage: 2 V or lessN.O./N.C. selectable*2External inputTuning /Transmission OFF selectableShort circuit current: 1 mA or less for NPN/2 mA or less for PNPFor the applied voltage, see the wiring diagrams in the instruction manual.For the input times, see the time charts in the instruction manual.*2Protection circuitProtection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connectionPower supplyPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption65 mA or less (without load) at 24 VDC;120 mA or less (without load) at 12 VDC *3Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or lessAmbient temperature-20 to +50 °C -4 to 122 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover: PPSU, Buttons: PESLens cover and display: PMMA (scratch-resistant coating),Spot adjustment dial: Iron (triiron tetraoxide coated)Connector ring: PMP, Connector socket: PEIWeightApprox. 110 g*1 When alternate frequencies are set, the response time increases by approximately 20%.*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*3 195 mA or less (at 10 V, with load)
|
In Stock
|
Subscribe
|
|
ModelLR-W70TypeSmall/Dual Spot Type2 m 6.56' cable typeDetecting distance30 to 70 mm 1.18" to 2.76"Min. spot diameterApprox. 1.6 x 2.9mm at 50 mm 0.06" × 0.11" at 1.97"Light sourceWhite LEDMutual interference reduction functionUp to 2 units when alternate frequencies setTimerOFF/ON delay/OFF delay/One-shotResponse time1-Spot Mode: 200 µs, 1 ms, 10 ms, 100 ms, 500 ms selectable2-Spot Mode, Difference Monitoring: 500 µs, 2.5 ms, 20 ms, 200 ms, 999 ms selectable2-Spot Mode, 2-Point Matching: 400 µs, 2 ms, 20 ms, 200 ms, 999 ms selectable*1I/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, remaining voltage: 2 V or lessN.O./N.C. selectable*2External inputTuning /Transmission OFF selectableShort circuit current: 1 mA or less for NPN/2 mA or less for PNPFor the applied voltage, see the wiring diagrams in the instruction manual.For the input times, see the time charts in the instruction manual.*2Protection circuitProtection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connectionPower supplyPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption60 mA or less (without load) at 24 VDC;110 mA or less (without load) at 12 VDC)*3Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or lessAmbient temperature-20 to +50 °C -4 to 122 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover: PPSU, Buttons: PES,Lens cover and display: PMMA (scratch-resistant coating),Cable bushing: PBT, Cable: PVCWeightApprox. 130 g (including cable)*1 When alternate frequencies are set, the response time increases by approximately 20%.*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*3 180 mA or less (at 10 V, with load)
|
In Stock
|
Subscribe
|
|
ModelLR-W70CTypeSmall/Dual Spot TypeM12 connector 4-pin typeDetecting distance30 to 70 mm 1.18" to 2.76"Min. spot diameterApprox. 1.6 x 2.9mm at 50 mm 0.06" × 0.11" at 1.97"Light sourceWhite LEDMutual interference reduction functionUp to 2 units when alternate frequencies setTimerOFF/ON delay/OFF delay/One-shotResponse time1-Spot Mode: 200 µs, 1 ms, 10 ms, 100 ms, 500 ms selectable2-Spot Mode, Difference Monitoring: 500 µs, 2.5 ms, 20 ms, 200 ms, 999 ms selectable2-Spot Mode, 2-Point Matching: 400 µs, 2 ms, 20 ms, 200 ms, 999 ms selectable*1I/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, remaining voltage: 2 V or lessN.O./N.C. selectable*2External inputTuning /Transmission OFF selectableShort circuit current: 1 mA or less for NPN/2 mA or less for PNPFor the applied voltage, see the wiring diagrams in the instruction manual.For the input times, see the time charts in the instruction manual.*2Protection circuitProtection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connectionPower supplyPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption60 mA or less (without load) at 24 VDC;110 mA or less (without load) at 12 VDC)*3Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or lessAmbient temperature-20 to +50 °C -4 to 122 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover: PPSU, Buttons: PES,Lens cover and display: PMMA (scratch-resistant coating),Connector ring: PMP, Connector socket: PEIWeightApprox. 75 g*1 When alternate frequencies are set, the response time increases by approximately 20%.*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*3 180 mA or less (at 10 V, with load)
|
In Stock
|
Subscribe
|
|
ModelLR-WF10TypeFiber Type2 m 6.56' cable typeDetecting distanceDetecting Distance and Min. Spot Diameter Based on Attached Fiber HeadMin. spot diameterLight sourceWhite LEDMutual interference reduction functionUp to 2 units when alternate frequencies setTimerOFF/ON delay/OFF delay/One-shotResponse time250 µs, 1 ms, 10 ms, 100 ms, 500 ms Selectable*1*2I/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, remaining voltage: 2 V or lessN.O./N.C. selectable*3External inputTuning /Transmission OFF selectableShort circuit current: 1 mA or less for NPN/2 mA or less for PNPFor the applied voltage, see the wiring diagrams in the instruction manual.For the input times, see the time charts in the instruction manual.*3Protection circuitProtection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connectionPower supplyPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption50 mA or less (without load) at 24 VDC;90 mA or less (without load) at 12 VDC*4Environmental resistanceEnclosure ratingIP65 (IEC60529)*5*6Ambient lightIncandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or lessAmbient temperature-20 to +45 °C -4 to 113 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover: PPSU, Buttons: PES,Display: PMMA (scratch-resistant coating),Cable bushing: PBT, Cable: PVC,Fiber locking mount: PBT, NBR, Silicone rubber, SUS304, SUSXM7Adapter: PBTWeightApprox. 150 g (including cable)*1 When alternate frequencies are set, the response time increases by approximately 20%.*2 When using the IO-Link communication, if the response time is set in 1ms or more, it becomes approximately 10% slower.*3 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*4 160 mA or less (at 10 V, with load)*5 When the following small-diameter fiber units (the diameter of the cable is ø1.3 ø0.05" or ø1.0 ø0.04") are used, the IP65 rating cannot be satisfied (FU-4F/66/91/93/43/63/63T etc.). When any small-diameter fiber units except for the above are used, IP65 is applied.*6 When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit, the IP65 enclosure rating cannot be satisfied.
|
In Stock
|
Subscribe
|
|
ModelLR-WF10CTypeFiber TypeM12 connector 4-pin typeDetecting distanceDetecting Distance and Min. Spot Diameter Based on Attached Fiber HeadMin. spot diameterLight sourceWhite LEDMutual interference reduction functionUp to 2 units when alternate frequencies setTimerOFF/ON delay/OFF delay/One-shotResponse time250 µs, 1 ms, 10 ms, 100 ms, 500 ms Selectable*1*2I/OControl outputNPN open collector/PNP open collector selectable30 VDC or less, 50 mA or less, remaining voltage: 2 V or lessN.O./N.C. selectable*3External inputTuning /Transmission OFF selectableShort circuit current: 1 mA or less for NPN/2 mA or less for PNPFor the applied voltage, see the wiring diagrams in the instruction manual.For the input times, see the time charts in the instruction manual.*3Protection circuitProtection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connectionPower supplyPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSCurrent consumption50 mA or less (without load) at 24 VDC;90 mA or less (without load) at 12 VDC*4Environmental resistanceEnclosure ratingIP65 (IEC60529)*5*6Ambient lightIncandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or lessAmbient temperature-20 to +45 °C -4 to 113 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: Zinc die cast (Nickel chrome plating),Indicator cover: PPSU, Buttons: PES,Display: PMMA (scratch-resistant coating),Connector ring: PMP, Connector socket: PEI,Fiber locking mount: PBT, NBR, Silicone rubber, SUS304, SUSXM7Adapter: PBTWeightApprox. 95 g*1 When alternate frequencies are set, the response time increases by approximately 20%.*2 When using the IO-Link communication, if the response time is set in 1ms or more, it becomes approximately 10% slower.*3 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.*4 160 mA or less (at 10 V, with load)*5 When the following small-diameter fiber units (the diameter of the cable is ø1.3 ø0.05" or ø1.0 ø0.04") are used, the IP65 rating cannot be satisfied (FU-4F/66/91/93/43/63/63T etc.). When any small-diameter fiber units except for the above are used, IP65 is applied.*6 When the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit, the IP65 enclosure rating cannot be satisfied.
|
In Stock
|
Subscribe
|
|
ModelLR-X100TypeCable TypeDetecting Distance25.0 to 100.0 mm 0.98" to 3.94"Standard Detectable Deviation1.0 mm 0.04"Display Resolution0.1 mm 0.004"Spot SizeApprox. 0.3 mm × 2 mm 0.012" × 0.08"(at a detecting distance of 100 mm 3.94")Response Time500 µs*1/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *330 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *3Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 16000 lux or lessSunlight: 16000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAccessoriesInstruction manual, laser warning labelWeightApprox. 90 g*1 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*2 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*3 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
|
In Stock
|
Subscribe
|
|
ModelLR-X100CTypeM8 Connector Type*1Detecting Distance25.0 to 100.0 mm 0.98" to 3.94"Standard Detectable Deviation1.0 mm 0.04"Display Resolution0.1 mm 0.004"Spot SizeApprox. 0.3 mm × 2 mm 0.012" × 0.08"(at a detecting distance of 100 mm 3.94")Response Time500 µs*2/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *430 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 16000 lux or lessSunlight: 16000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAmplifier M8 Connector: SUS303AccessoriesInstruction manual, laser warning labelWeight Approx. 35 g*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.*2 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*3 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*4 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
|
In Stock
|
Subscribe
|
|
ModelLR-X250TypeCable TypeDetecting Distance30 to 250 mm 1.18" to 9.84"Standard Detectable Deviation30 to 180 mm: 9 mm 1.18" to 7.09": 0.35"180 to 250 mm: 18 mm 7.09" to 9.84": 0.71"Display Resolution1 to 2 mm 0.04" to 0.08"Spot SizeApprox. 0.8 mm × 1.2 mm 0.03" × 0.05"(at a detecting distance of 250 mm 9.84")Response Time500 µs*1/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *330 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *3Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 8000 lux or lessSunlight: 8000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAccessoriesInstruction manual, laser warning labelWeightApprox. 90 g*1 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*2 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*3 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
|
In Stock
|
Subscribe
|
|
ModelLR-X250CTypeM8 Connector Type*1Detecting Distance30 to 250 mm 1.18" to 9.84"Standard Detectable Deviation30 to 180 mm: 9 mm 1.18" to 7.09": 0.35"180 to 250 mm: 18 mm 7.09" to 9.84": 0.71"Display Resolution1 to 2 mm 0.04" to 0.08"Spot SizeApprox. 0.8 mm × 1.2 mm 0.03" × 0.05"(at a detecting distance of 250 mm 9.84")Response Time500 µs*2/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *430 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 8000 lux or lessSunlight: 8000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAmplifier M8 Connector: SUS303AccessoriesInstruction manual, laser warning labelWeight Approx. 35 g*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.*2 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*3 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*4 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
|
In Stock
|
Subscribe
|
|
ModelLR-X50TypeCable TypeDetecting Distance25.0 to 50.0 mm 0.98" to 1.97"Standard Detectable Deviation0.5 mm 0.02"Display Resolution0.1 mm 0.004"Spot SizeApprox. 0.2 mm × 1.5 mm 0.008" × 0.06"(at a detecting distance of 50 mm 1.97")Response Time500 µs*1/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *330 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *3Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 16000 lux or lessSunlight: 16000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAccessoriesInstruction manual, laser warning labelWeightApprox. 90 g*1 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*2 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*3 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
|
In Stock
|
Subscribe
|
|
ModelLR-X50CTypeM8 Connector Type*1Detecting Distance25.0 to 50.0 mm 0.98" to 1.97"Standard Detectable Deviation0.5 mm 0.02"Display Resolution0.1 mm 0.004"Spot SizeApprox. 0.2 mm × 1.5 mm 0.008" × 0.06"(at a detecting distance of 50 mm 1.97")Response Time500 µs*2/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *430 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 16000 lux or lessSunlight: 16000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAmplifier M8 Connector: SUS303AccessoriesInstruction manual, laser warning labelWeight Approx. 35 g*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.*2 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*3 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*4 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
|
In Stock
|
Subscribe
|
|
ModelLR-XB1AppearanceFine-Tuning Mounting Bracket (Includes Sensor Head Fastening Screws × 2 Mounting Bracket Locking Screws × 2/Plate Nut × 1)MaterialZinc Nickel Plating SUS304 PPS OtherWeightApprox. 30 g
|
In Stock
|
Subscribe
|
|
ModelLR-XH100TypeCable Length: 2 m 6.6'Detecting Distance25.0 to 100.0 mm 0.98" to 3.94"Standard Detectable Deviation1.0 mm 0.04"Display Resolution0.1 mm 0.004"Spot SizeApprox. 0.3 mm × 2 mm 0.012" × 0.08"(at a detecting distance of 100 mm 3.94")Light SourceTypeGreen laser (505 nm)Laser ClassClass 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or lessAmbient temperature-10°C to +50°C 14°F to 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G); 6 times each for X, Y, and Z axesMaterialCase: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)AccessoriesLaser warning labelWeightapprox. 75 g*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.
|
In Stock
|
Subscribe
|
|
ModelLR-XH250TypeCable Length: 2 m 6.6'Detecting Distance30 to 250 mm 1.18" to 9.84"Standard Detectable Deviation30 to 180 mm: 9 mm, 180 to 250 mm: 18 mm1.18" to 7.09": 0.35", 7.09" to 9.84": 0.71Display Resolution1 to 2 mm 0.04" to 0.08"Spot SizeApprox. 0.8 mm × 1.2 mm 0.03" × 0.05"(at a detecting distance of 250 mm 9.84")Light SourceTypeGreen laser (505 nm)Laser ClassClass 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 8000 lux or less, Sunlight: 8000 lux or lessAmbient temperature-10°C to +50°C 14°F to 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G); 6 times each for X, Y, and Z axesMaterialCase: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)AccessoriesLaser warning labelWeightapprox. 75 g*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.
|
In Stock
|
Subscribe
|
|
ModelLR-XN11CTypeNPN Output/PNP Output (Selectable output)Cable/ConnectorM8 connector*1Main Unit/Expansion UnitMain Unit (expansion not possible)No. of Control Outputs2*2No. of External Inputs1*2Response Time500 µs*3/1 ms/3 ms/10 ms/200 ms SelectableIO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputOpen collector, 30 VDC or lower, N.O./N.C.100 mA or lower for 1 output; 100 mA or lower in total for 2 outputsResidual voltage NPN: 1.4 V or lower (output current: 10 mA or lower)/2 V or lower (output current: 10 to 100 mA), PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA)External InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectableShort circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)Unit Expansion—Protection CircuitProtection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connectionNumber of Interference Prevention Devices—Power supplyPower voltage16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current)Environmental resistanceAmbient temperature−20 to +55°C -4°F to 131°F (no freezing)*5Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directionsShock resistance500 m/s2 (50G); 3 times each for X, Y, and Z axesCase MaterialMain Unit and Cover: PolycarbonateAccessoriesInstruction manualWeightApprox. 22 g*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.*2 Output 2 and the external input are selectable.*3 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.· The interference prevention function is not supported*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.*5 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F
|
In Stock
|
Subscribe
|
|
ModelLR-ZB100C3P*1TypeDistance based laser sensorAppearanceRectangularOutputPNPCable connectionM8 connector, 3-pinDetectable distance35 to 100 mm 1.38" to 3.94" (650 to 0)*2Standard detectable deviation35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06"50 to 100 mm 1.97" to 3.94": 3 mm 0.12"Display resolution2 (0.2 mm 0.008")Spot sizeApprox. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94"Response time1.5 ms / 10 ms / 50 ms selectableLight sourceTypeRed laser (660 nm)Laser classClass 1 laser product(IEC60825-1, FDA (CDRH) Part1040.10*3)FunctionIndicator3-digit 7-segment display (red),output indicator (yellow),DATUM indicator (orange),1 spot indicator (green)TimerOFF/ON delay/OFF delay/One-shotSpecificationsPower voltage10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPSPower consumption450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)Control outputPNP Open collector,Applied voltage 30 VDC or less, Control current 100 mA or less, Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mAProtection circuitProtection against reverse power connection, output overcurrent, output surge, reverse output connectionOutput operationLight-ON / Dark-ON selectableEnvironmental resistanceEnclosure ratingIP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*4, Diversey*4Insulation resistance20 MΩ or more (500 VDC)Ambient lightIncandescent lamp: 4,000 lux or lessSunlight: 8,000 lux or less*5Ambient temperature-10 to +50 °C 14 to 122 °F (No freezing)Storage temperature-25 to +75 °C -13 to 167 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Withstand voltage1,000 VAC, 50/60 Hz, 1 minVibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKMAccompanying itemsInstruction Manual,Certification/Identification label (FDA)WeightApprox. 55 g*1 M8 connector (3-pin) type does not include the external input function.*2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.*3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.*4 Have passed resistance tests with cleaning agents from multiple manufactures.*5 When the response time is 10 ms
|
In Stock
|
Subscribe
|
Unsubscribe